| Max Speed | 6000rpm | Motor | Variable frequency motor | 
| Max Centrifugal Force | 5200Xg | Display | LCD touch screen | 
| Max Capacity | 4*750ml(4000rpm) | Parameters setting | Input numbers directly | 
| Speed Accuracy | ±10rpm | Intelligent status reminding | Display the status in real time | 
| Temp. Accuracy | ±1℃ | Timing models | Count or countdown | 
| Temp. range | -20℃ ~40℃ | Can store programs | 1000 | 
| Timing range | 1s-99H59mi59s | Can store usage records | 1000 | 
| Noise | ≤56dB(A) | Adjustable acceleration and deceleration rate | 40 levels | 
| Power Supply | AC 220V 50HZ 15A | Temperature control | PID dynamic temperature control | 
| Dimension | 600*680*420mm (L*W*H) | Balance monitoring | Three-axis gyroscope dynamically monitors balance | 
| Weight | 108kg | Intelligent protection | 22 kinds of protections | 
| Power | 1500W | Password lock function | Yes | 

 Refrigeration: • Imported compressor unit. • CFC-free refrigerant. • PID dynamically control temperature. • ±1℃ high temperature accuracy. • Temperature range from -20°C to 40°C in 1°C steps • Temperature sensor inside the chamber. • With ECO energy saving module.  Ensure Safety: • 22 protections such as door,overspeed,overtemperature,overpressure and overheating • Electronic door lock,controlled by independent motor. • Emergency lid-lock release • Lid can only be opened when completely stop running. • Port in the lid for calibration and operation checking. • Hydraulic rods support the lid.  Good components: • Motor: Variable frequency motor---stable running,maintenance free,long life. • Housing: thick and strong steel • Chamber: Medical grade 316 stainless steel--- anticorrosion and easy to clean • Rotor:Stainless steel swing out rotor.
Refrigeration: • Imported compressor unit. • CFC-free refrigerant. • PID dynamically control temperature. • ±1℃ high temperature accuracy. • Temperature range from -20°C to 40°C in 1°C steps • Temperature sensor inside the chamber. • With ECO energy saving module.  Ensure Safety: • 22 protections such as door,overspeed,overtemperature,overpressure and overheating • Electronic door lock,controlled by independent motor. • Emergency lid-lock release • Lid can only be opened when completely stop running. • Port in the lid for calibration and operation checking. • Hydraulic rods support the lid.  Good components: • Motor: Variable frequency motor---stable running,maintenance free,long life. • Housing: thick and strong steel • Chamber: Medical grade 316 stainless steel--- anticorrosion and easy to clean • Rotor:Stainless steel swing out rotor.